{"title":"Best selling","description":"","products":[{"product_id":"r-454b-refrigerant-20-lb","title":"R-454B Refrigerant 20 lb","description":"\u003cstyle\u003e\n\/* ===== PRODUCT DESCRIPTION – SHRINE SAFE ===== *\/\n.rd-product-wrap{\nmax-width:900px;\nmargin:40px auto;\nfont-family:Arial,Helvetica,sans-serif;\ncolor:#111;\n}\n\n\/* SECTION *\/\n.rd-section{\nmargin-bottom:40px;\npadding:30px;\nborder:1px solid #eee;\nborder-radius:16px;\nbackground:#ffffff;\n}\n\n\/* TITLES *\/\n.rd-title{\nfont-size:28px;\nfont-weight:700;\nmargin-bottom:16px;\n}\n\n.rd-subtitle{\nfont-size:18px;\nfont-weight:600;\nmargin-bottom:12px;\ncolor:#004de4;\n}\n\n\/* TEXT *\/\n.rd-text{\nfont-size:16px;\nline-height:1.75;\ncolor:#444;\nmargin-bottom:16px;\n}\n\n\/* LIST *\/\n.rd-list{\npadding-left:20px;\nmargin-top:10px;\n}\n\n.rd-list li{\nmargin-bottom:10px;\nline-height:1.6;\n}\n\n\/* BADGES *\/\n.rd-badges{\ndisplay:flex;\ngap:12px;\nflex-wrap:wrap;\nmargin-top:16px;\n}\n\n.rd-badge{\nbackground:#f3f6ff;\ncolor:#004de4;\npadding:8px 14px;\nborder-radius:20px;\nfont-size:14px;\nfont-weight:600;\nborder:1px solid #dfe6ff;\n}\n\n\/* SHIPPING BOX *\/\n.rd-shipping{\nbackground:#f9fafc;\nborder:1px solid #e5e7eb;\nborder-radius:12px;\npadding:20px;\nfont-size:15px;\nline-height:1.6;\n}\n\n\/* MOBILE *\/\n@media(max-width:768px){\n.rd-title{font-size:24px;}\n.rd-section{padding:20px;}\n}\n\u003c\/style\u003e\n\u003cdiv class=\"rd-product-wrap\"\u003e\n\u003c!-- OVERVIEW --\u003e\n\u003cdiv class=\"rd-section\"\u003e\n\u003cdiv class=\"rd-title\"\u003eHoneywell Solstice® R-454B Refrigerant\u003c\/div\u003e\n\u003cp class=\"rd-text\"\u003eHoneywell Solstice® R-454B is a next-generation, low-GWP refrigerant engineered as an optimized replacement for R-410A. It delivers comparable cooling capacity and improved energy efficiency while reducing global warming potential (GWP) by approximately \u003cstrong\u003e78%\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"rd-text\"\u003eDesigned for a smooth transition from R-410A, R-454B minimizes redesign costs and limits the need for major equipment modifications. This makes it an ideal solution for manufacturers and HVAC professionals seeking compliance with evolving environmental regulations without sacrificing performance.\u003c\/p\u003e\n\u003cdiv class=\"rd-badges\"\u003e\n\u003cdiv class=\"rd-badge\"\u003e78% Lower GWP\u003c\/div\u003e\n\u003cdiv class=\"rd-badge\"\u003eR-410A Replacement\u003c\/div\u003e\n\u003cdiv class=\"rd-badge\"\u003eHigh Efficiency\u003c\/div\u003e\n\u003cdiv class=\"rd-badge\"\u003eARI-700 Certified\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- PERFORMANCE --\u003e\n\u003cdiv class=\"rd-section\"\u003e\n\u003cdiv class=\"rd-title\"\u003ePerformance Advantages\u003c\/div\u003e\n\u003cp class=\"rd-text\"\u003eWith a high critical temperature and a wide operating envelope, Solstice® R-454B performs exceptionally well across a broad range of conditions, including normal and high ambient environments. Its strong performance at low evaporating temperatures ensures reliable operation in demanding HVAC applications.\u003c\/p\u003e\n\u003cul class=\"rd-list\"\u003e\n\u003cli\u003eComparable capacity to R-410A with improved efficiency\u003c\/li\u003e\n\u003cli\u003eExcellent performance in high ambient conditions\u003c\/li\u003e\n\u003cli\u003eOptimized for modern HVAC system requirements\u003c\/li\u003e\n\u003cli\u003eReduced environmental impact compared to legacy refrigerants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003cdiv class=\"rd-section\"\u003e\n\u003cdiv class=\"rd-title\"\u003eRecommended Applications\u003c\/div\u003e\n\u003cul class=\"rd-list\"\u003e\n\u003cli\u003eDirect Expansion (DX) chillers\u003c\/li\u003e\n\u003cli\u003eHigh-pressure heat pumps\u003c\/li\u003e\n\u003cli\u003eResidential and light commercial air conditioning systems\u003c\/li\u003e\n\u003cli\u003eCommercial packaged HVAC units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- QUALITY --\u003e\n\u003cdiv class=\"rd-section\"\u003e\n\u003cdiv class=\"rd-title\"\u003eProduct Quality \u0026amp; Assurance\u003c\/div\u003e\n\u003cp class=\"rd-text\"\u003eWhen purchasing from \u003cstrong\u003eFriglab\u003c\/strong\u003e, you can be confident that all refrigerants are brand new, 100% virgin products. Every cylinder meets or exceeds \u003cstrong\u003eARI-700 purity standards\u003c\/strong\u003e to ensure safety, consistency, and reliable system performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- SHIPPING --\u003e\n\u003c\/div\u003e","brand":"Friglab","offers":[{"title":"1 Cylinder","offer_id":54108875850057,"sku":null,"price":99.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/9691\/0409\/files\/1.png?v=1774879506"},{"product_id":"22lb-r454b-freon-refrigerant-gas","title":"22LB R454B R-454B Freon Refrigerant Gas","description":"\u003cp data-start=\"73\" data-end=\"457\"\u003e\u003cstrong data-start=\"73\" data-end=\"457\"\u003eR-454B is a next-generation refrigerant designed to replace R-410A in new HVAC systems. Offering similar performance with significantly lower environmental impact, it is the preferred low-GWP solution for air conditioning and heat pump manufacturers worldwide. As global regulations tighten, R-454B provides a reliable and future-compliant alternative for high-efficiency systems.\u003c\/strong\u003e\u003c\/p\u003e \u003chr data-start=\"459\" data-end=\"462\"\u003e \u003cp data-start=\"464\" data-end=\"493\"\u003e\u003cstrong data-start=\"464\" data-end=\"493\"\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e \u003cp data-start=\"495\" data-end=\"713\"\u003e✅ \u003cstrong data-start=\"497\" data-end=\"523\"\u003eUltra-Low GWP Solution\u003c\/strong\u003e\u003cbr data-start=\"523\" data-end=\"526\"\u003eWith a Global Warming Potential (GWP) of just \u003cstrong data-start=\"572\" data-end=\"579\"\u003e466\u003c\/strong\u003e, R-454B reduces climate impact by nearly \u003cstrong data-start=\"621\" data-end=\"628\"\u003e80%\u003c\/strong\u003e compared to R-410A (GWP ~2,088), helping meet international environmental standards.\u003c\/p\u003e \u003cp data-start=\"715\" data-end=\"886\"\u003e✅ \u003cstrong data-start=\"717\" data-end=\"749\"\u003eExcellent System Performance\u003c\/strong\u003e\u003cbr data-start=\"749\" data-end=\"752\"\u003eDelivers comparable capacity and energy efficiency to R-410A while enabling reduced charge sizes and better environmental credentials.\u003c\/p\u003e \u003cp data-start=\"888\" data-end=\"1060\"\u003e✅ \u003cstrong data-start=\"890\" data-end=\"917\"\u003eMild Flammability (A2L)\u003c\/strong\u003e\u003cbr data-start=\"917\" data-end=\"920\"\u003eClassified as \u003cstrong data-start=\"934\" data-end=\"941\"\u003eA2L\u003c\/strong\u003e – non-toxic and mildly flammable – suitable for use in new system designs built to handle low-GWP refrigerants safely.\u003c\/p\u003e \u003cp data-start=\"1062\" data-end=\"1219\"\u003e✅ \u003cstrong data-start=\"1064\" data-end=\"1087\"\u003eHVAC Industry Ready\u003c\/strong\u003e\u003cbr data-start=\"1087\" data-end=\"1090\"\u003eWidely adopted by major manufacturers for new air conditioning, rooftop units, VRF systems, and heat pumps. Not for retrofit use.\u003c\/p\u003e \u003chr data-start=\"1221\" data-end=\"1224\"\u003e \u003cp data-start=\"1226\" data-end=\"1256\"\u003e\u003cstrong data-start=\"1226\" data-end=\"1256\"\u003eR-454B Physical Properties\u003c\/strong\u003e\u003c\/p\u003e \u003cul data-start=\"1258\" data-end=\"1549\"\u003e \u003cli data-start=\"1258\" data-end=\"1318\"\u003e \u003cp data-start=\"1260\" data-end=\"1318\"\u003e\u003cstrong data-start=\"1260\" data-end=\"1285\"\u003eChemical Composition:\u003c\/strong\u003e R-32 (68.9%), R-1234yf (31.1%)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1319\" data-end=\"1351\"\u003e \u003cp data-start=\"1321\" data-end=\"1351\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1343\"\u003eMolecular Formula:\u003c\/strong\u003e Blend\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1352\" data-end=\"1392\"\u003e \u003cp data-start=\"1354\" data-end=\"1392\"\u003e\u003cstrong data-start=\"1354\" data-end=\"1372\"\u003eBoiling Point:\u003c\/strong\u003e -54.4°C (-65.9°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1393\" data-end=\"1436\"\u003e \u003cp data-start=\"1395\" data-end=\"1436\"\u003e\u003cstrong data-start=\"1395\" data-end=\"1430\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 466\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1437\" data-end=\"1479\"\u003e \u003cp data-start=\"1439\" data-end=\"1479\"\u003e\u003cstrong data-start=\"1439\" data-end=\"1475\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1480\" data-end=\"1549\"\u003e \u003cp data-start=\"1482\" data-end=\"1549\"\u003e\u003cstrong data-start=\"1482\" data-end=\"1515\"\u003eASHRAE Safety Classification:\u003c\/strong\u003e A2L (Mildly Flammable, Non-Toxic)\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1551\" data-end=\"1554\"\u003e \u003cp data-start=\"1556\" data-end=\"1577\"\u003e\u003cstrong data-start=\"1556\" data-end=\"1577\"\u003eMain Applications\u003c\/strong\u003e\u003c\/p\u003e \u003cp data-start=\"1579\" data-end=\"1705\"\u003e\u003cstrong data-start=\"1579\" data-end=\"1618\"\u003eResidential \u0026amp; Light Commercial HVAC\u003c\/strong\u003e\u003cbr data-start=\"1618\" data-end=\"1621\"\u003eEngineered for new central air conditioning systems, mini-splits, and rooftop units.\u003c\/p\u003e \u003cp data-start=\"1707\" data-end=\"1819\"\u003e\u003cstrong data-start=\"1707\" data-end=\"1732\"\u003eCommercial Heat Pumps\u003c\/strong\u003e\u003cbr data-start=\"1732\" data-end=\"1735\"\u003eIdeal for high-efficiency buildings and environmentally compliant new installations.\u003c\/p\u003e \u003cp data-start=\"1821\" data-end=\"1911\"\u003e\u003cstrong data-start=\"1821\" data-end=\"1839\"\u003eVRF \u0026amp; Chillers\u003c\/strong\u003e\u003cbr data-start=\"1839\" data-end=\"1842\"\u003eOptimized for advanced system designs requiring low-GWP refrigerants.\u003c\/p\u003e \u003chr data-start=\"1913\" data-end=\"1916\"\u003e \u003cp data-start=\"1918\" data-end=\"1954\"\u003e\u003cstrong data-start=\"1918\" data-end=\"1954\"\u003eNote on Environmental Compliance\u003c\/strong\u003e\u003c\/p\u003e \u003cp data-start=\"1956\" data-end=\"2257\"\u003eR-454B is compliant with current and upcoming F-Gas and AIM Act regulations. While it is not suitable for retrofitting R-410A systems, it plays a critical role in the global transition toward sustainable HVAC technology. Always follow certified A2L handling protocols and local regulations during use.\u003c\/p\u003e \u003chr data-start=\"2259\" data-end=\"2262\"\u003e \u003cp data-start=\"2264\" data-end=\"2275\"\u003e\u003cstrong data-start=\"2264\" data-end=\"2275\"\u003ePackage\u003c\/strong\u003e\u003c\/p\u003e \u003cul data-start=\"2277\" data-end=\"2505\"\u003e \u003cli data-start=\"2277\" data-end=\"2310\"\u003e \u003cp data-start=\"2279\" data-end=\"2310\"\u003e\u003cstrong data-start=\"2279\" data-end=\"2294\"\u003eNet Weight:\u003c\/strong\u003e 22lb (10kg)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2311\" data-end=\"2357\"\u003e \u003cp data-start=\"2313\" data-end=\"2357\"\u003e\u003cstrong data-start=\"2313\" data-end=\"2331\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel bottle\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2358\" data-end=\"2505\"\u003e \u003cp data-start=\"2360\" data-end=\"2505\"\u003e\u003cstrong data-start=\"2360\" data-end=\"2372\"\u003eStorage:\u003c\/strong\u003e Store upright in a cool, dry, and well-ventilated place. Avoid direct sunlight, open flames, or temperatures exceeding 52°C (125°F).\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Friglab","offers":[{"title":"Default Title","offer_id":54108876734793,"sku":"pz-R454","price":399.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/9691\/0409\/files\/1_050f662a-ac50-4e3b-bf37-aa20c2f23bc5.png?v=1774879517"},{"product_id":"r32-freon-refrigerant","title":"20.9LB R32 R-32 Freon Refrigerant Gas","description":"\u003cp data-start=\"173\" data-end=\"569\" class=\"\"\u003eR-32 (Difluoromethane) is a next-generation single-component HFC refrigerant known for its superior energy efficiency and significantly lower Global Warming Potential (GWP) compared to traditional blends like R-410A. With increasing environmental regulations worldwide, R-32 has become the preferred refrigerant in modern air conditioning systems designed for sustainability and high performance.\u003c\/p\u003e \u003chr data-start=\"571\" data-end=\"574\" class=\"\"\u003e \u003ch5 data-start=\"576\" data-end=\"610\"\u003e\u003cstrong data-start=\"580\" data-end=\"610\"\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"612\" data-end=\"766\" class=\"\"\u003e✅ \u003cstrong data-start=\"614\" data-end=\"635\"\u003eLow GWP solution:\u003c\/strong\u003e R-32 has a GWP of only 675—approximately 70% lower than R-410A—making it a climate-conscious choice for eco-friendly HVAC systems.\u003c\/p\u003e \u003cp data-start=\"768\" data-end=\"930\" class=\"\"\u003e✅ \u003cstrong data-start=\"770\" data-end=\"797\"\u003eHigh energy efficiency:\u003c\/strong\u003e Offers excellent heat transfer and refrigeration capacity, leading to lower electricity consumption and improved system performance.\u003c\/p\u003e \u003cp data-start=\"932\" data-end=\"1088\" class=\"\"\u003e✅ \u003cstrong data-start=\"934\" data-end=\"955\"\u003ePure refrigerant:\u003c\/strong\u003e As a single-component refrigerant, R-32 is easier to recover and recycle, with no glide issues compared to multi-blend refrigerants.\u003c\/p\u003e \u003cp data-start=\"1090\" data-end=\"1268\" class=\"\"\u003e✅ \u003cstrong data-start=\"1092\" data-end=\"1116\"\u003eNext-gen compatible:\u003c\/strong\u003e Supported by many new high-efficiency air conditioning and heat pump systems; ideal for forward-looking installations and retrofits (where applicable).\u003c\/p\u003e \u003chr data-start=\"1270\" data-end=\"1273\" class=\"\"\u003e \u003ch5 data-start=\"1275\" data-end=\"1307\"\u003e\u003cstrong data-start=\"1279\" data-end=\"1307\"\u003eR-32 Physical Properties\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"1309\" data-end=\"1506\"\u003e \u003cli data-start=\"1309\" data-end=\"1347\" class=\"\"\u003e \u003cp data-start=\"1311\" data-end=\"1347\" class=\"\"\u003e\u003cstrong data-start=\"1311\" data-end=\"1329\"\u003eChemical Name:\u003c\/strong\u003e Difluoromethane\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1348\" data-end=\"1380\" class=\"\"\u003e \u003cp data-start=\"1350\" data-end=\"1380\" class=\"\"\u003e\u003cstrong data-start=\"1350\" data-end=\"1372\"\u003eMolecular Formula:\u003c\/strong\u003e CH₂F₂\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1381\" data-end=\"1419\" class=\"\"\u003e \u003cp data-start=\"1383\" data-end=\"1419\" class=\"\"\u003e\u003cstrong data-start=\"1383\" data-end=\"1401\"\u003eBoiling Point:\u003c\/strong\u003e -51.7°C (-61°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1420\" data-end=\"1463\" class=\"\"\u003e \u003cp data-start=\"1422\" data-end=\"1463\" class=\"\"\u003e\u003cstrong data-start=\"1422\" data-end=\"1457\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 675\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1464\" data-end=\"1506\" class=\"\"\u003e \u003cp data-start=\"1466\" data-end=\"1506\" class=\"\"\u003e\u003cstrong data-start=\"1466\" data-end=\"1502\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1508\" data-end=\"1511\" class=\"\"\u003e \u003ch5 data-start=\"1513\" data-end=\"1538\"\u003e\u003cstrong data-start=\"1517\" data-end=\"1538\"\u003eMain Applications\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1540\" data-end=\"1687\" class=\"\"\u003e\u003cstrong data-start=\"1540\" data-end=\"1587\"\u003eResidential and Commercial Air Conditioning\u003c\/strong\u003e\u003cbr data-start=\"1587\" data-end=\"1590\"\u003eUsed in new-generation A\/C systems designed for higher efficiency and lower environmental impact.\u003c\/p\u003e \u003cp data-start=\"1689\" data-end=\"1821\" class=\"\"\u003e\u003cstrong data-start=\"1689\" data-end=\"1703\"\u003eHeat Pumps\u003c\/strong\u003e\u003cbr data-start=\"1703\" data-end=\"1706\"\u003ePopular choice in modern high-performance heat pump systems for both residential and light commercial environments.\u003c\/p\u003e \u003cp data-start=\"1823\" data-end=\"1958\" class=\"\"\u003e\u003cstrong data-start=\"1823\" data-end=\"1850\"\u003eNext-Gen HVAC Equipment\u003c\/strong\u003e\u003cbr data-start=\"1850\" data-end=\"1853\"\u003eAn ideal replacement in systems built to operate with low-GWP refrigerants and advanced safety standards.\u003c\/p\u003e \u003chr data-start=\"1960\" data-end=\"1963\" class=\"\"\u003e \u003ch5 data-start=\"1965\" data-end=\"2017\"\u003e\u003cstrong data-start=\"1969\" data-end=\"2015\"\u003eNote on Environmental \u0026amp; Safety Regulations\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"2018\" data-end=\"2270\" class=\"\"\u003eWhile R-32 has no ozone depletion potential and a low GWP, it is classified as A2L (mildly flammable). Proper handling, installation, and ventilation precautions must be observed. Always follow local safety codes and regulations when working with R-32.\u003c\/p\u003e \u003chr data-start=\"2272\" data-end=\"2275\" class=\"\"\u003e \u003ch5 data-start=\"2277\" data-end=\"2292\"\u003e\u003cstrong data-start=\"2281\" data-end=\"2292\"\u003ePackage\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"2294\" data-end=\"2562\"\u003e \u003cli data-start=\"2294\" data-end=\"2356\" class=\"\"\u003e \u003cp data-start=\"2296\" data-end=\"2356\" class=\"\"\u003e\u003cstrong data-start=\"2296\" data-end=\"2310\"\u003ePackaging:\u003c\/strong\u003e Net Weight 9.5kg\/bottle (Net Weight 20.9lb)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2357\" data-end=\"2405\" class=\"\"\u003e \u003cp data-start=\"2359\" data-end=\"2405\" class=\"\"\u003e\u003cstrong data-start=\"2359\" data-end=\"2377\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel cylinder\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2406\" data-end=\"2562\" class=\"\"\u003e \u003cp data-start=\"2408\" data-end=\"2562\" class=\"\"\u003e\u003cstrong data-start=\"2408\" data-end=\"2420\"\u003eStorage:\u003c\/strong\u003e Store in a dry, cool, and well-ventilated area. Keep away from open flames and direct sunlight. Handle with appropriate leak-proof equipment.\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Friglab","offers":[{"title":"Default Title","offer_id":54108878799177,"sku":"PZ-32","price":99.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/9691\/0409\/files\/R32_574fb931-38dd-487c-a8bd-43239267a7b3.jpg?v=1774879520"},{"product_id":"r404a-freon-refrigerant","title":"24LB R404A R-404A Freon Refrigerant Gas","description":"\u003cp data-start=\"160\" data-end=\"505\" class=\"\"\u003eR-404A is a widely used HFC blend refrigerant, specifically formulated to deliver reliable, low-temperature cooling in commercial refrigeration systems. As a non-ozone depleting replacement for R-502 and CFC blends, R-404A is the industry standard for food storage, transport refrigeration, and other demanding low- and medium-temp applications.\u003c\/p\u003e \u003chr data-start=\"507\" data-end=\"510\" class=\"\"\u003e \u003ch5 data-start=\"512\" data-end=\"546\"\u003e\u003cstrong data-start=\"516\" data-end=\"546\"\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"548\" data-end=\"739\" class=\"\"\u003e✅ \u003cstrong data-start=\"550\" data-end=\"584\"\u003eSuperior low-temp performance:\u003c\/strong\u003e Designed to provide consistent cooling even at very low temperatures—ideal for frozen food storage, supermarket refrigeration, and refrigerated transport.\u003c\/p\u003e \u003cp data-start=\"741\" data-end=\"907\" class=\"\"\u003e✅ \u003cstrong data-start=\"743\" data-end=\"765\"\u003eR-502 replacement:\u003c\/strong\u003e Perfect retrofit solution for systems originally using R-502, offering comparable thermodynamic performance with better environmental safety.\u003c\/p\u003e \u003cp data-start=\"909\" data-end=\"1053\" class=\"\"\u003e✅ \u003cstrong data-start=\"911\" data-end=\"935\"\u003eNon-ozone depleting:\u003c\/strong\u003e R-404A contains no chlorine, giving it an ODP of 0 and meeting global environmental regulations for ozone protection.\u003c\/p\u003e \u003cp data-start=\"1055\" data-end=\"1199\" class=\"\"\u003e✅ \u003cstrong data-start=\"1057\" data-end=\"1082\"\u003eSystem compatibility:\u003c\/strong\u003e Works with synthetic lubricants such as POE oil, and compatible with many components designed for HFC-based systems.\u003c\/p\u003e \u003chr data-start=\"1201\" data-end=\"1204\" class=\"\"\u003e \u003ch5 data-start=\"1206\" data-end=\"1240\"\u003e\u003cstrong data-start=\"1210\" data-end=\"1240\"\u003eR-404A Physical Properties\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"1242\" data-end=\"1438\"\u003e \u003cli data-start=\"1242\" data-end=\"1310\" class=\"\"\u003e \u003cp data-start=\"1244\" data-end=\"1310\" class=\"\"\u003e\u003cstrong data-start=\"1244\" data-end=\"1269\"\u003eChemical Composition:\u003c\/strong\u003e R-125 (44%), R-143a (52%), R-134a (4%)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1311\" data-end=\"1349\" class=\"\"\u003e \u003cp data-start=\"1313\" data-end=\"1349\" class=\"\"\u003e\u003cstrong data-start=\"1313\" data-end=\"1331\"\u003eBoiling Point:\u003c\/strong\u003e -46.1°C (-51°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1350\" data-end=\"1395\" class=\"\"\u003e \u003cp data-start=\"1352\" data-end=\"1395\" class=\"\"\u003e\u003cstrong data-start=\"1352\" data-end=\"1387\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 3,922\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1396\" data-end=\"1438\" class=\"\"\u003e \u003cp data-start=\"1398\" data-end=\"1438\" class=\"\"\u003e\u003cstrong data-start=\"1398\" data-end=\"1434\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1440\" data-end=\"1443\" class=\"\"\u003e \u003ch5 data-start=\"1445\" data-end=\"1470\"\u003e\u003cstrong data-start=\"1449\" data-end=\"1470\"\u003eMain Applications\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1472\" data-end=\"1622\" class=\"\"\u003e\u003cstrong data-start=\"1472\" data-end=\"1512\"\u003eCommercial Freezers and Cold Storage\u003c\/strong\u003e\u003cbr data-start=\"1512\" data-end=\"1515\"\u003eIdeal for supermarket freezers, walk-in coolers, and industrial cold rooms requiring sub-zero temperatures.\u003c\/p\u003e \u003cp data-start=\"1624\" data-end=\"1762\" class=\"\"\u003e\u003cstrong data-start=\"1624\" data-end=\"1651\"\u003eTransport Refrigeration\u003c\/strong\u003e\u003cbr data-start=\"1651\" data-end=\"1654\"\u003eWidely used in refrigerated trucks, trailers, and containers where stable and powerful cooling is essential.\u003c\/p\u003e \u003cp data-start=\"1764\" data-end=\"1900\" class=\"\"\u003e\u003cstrong data-start=\"1764\" data-end=\"1790\"\u003eFood Service Equipment\u003c\/strong\u003e\u003cbr data-start=\"1790\" data-end=\"1793\"\u003eFound in ice cream machines, reach-in freezers, and frozen food display cabinets in restaurants and retail.\u003c\/p\u003e \u003chr data-start=\"1902\" data-end=\"1905\" class=\"\"\u003e \u003ch5 data-start=\"1907\" data-end=\"1950\"\u003e\u003cstrong data-start=\"1911\" data-end=\"1948\"\u003eNote on Environmental Regulations\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1951\" data-end=\"2194\" class=\"\"\u003eDue to its high GWP, R-404A is subject to phasedown under HFC regulations in many regions. It remains a crucial refrigerant for servicing and maintaining legacy systems. Always ensure proper recovery and handling in compliance with local laws.\u003c\/p\u003e \u003chr data-start=\"2196\" data-end=\"2199\" class=\"\"\u003e \u003ch5 data-start=\"2201\" data-end=\"2216\"\u003e\u003cstrong data-start=\"2205\" data-end=\"2216\"\u003ePackage\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"2218\" data-end=\"2468\"\u003e \u003cli data-start=\"2218\" data-end=\"2279\" class=\"\"\u003e \u003cp data-start=\"2220\" data-end=\"2279\" class=\"\"\u003e\u003cstrong data-start=\"2220\" data-end=\"2234\"\u003ePackaging:\u003c\/strong\u003e Net Weight 10.9kg\/bottle (Net Weight 24lb)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2280\" data-end=\"2328\" class=\"\"\u003e \u003cp data-start=\"2282\" data-end=\"2328\" class=\"\"\u003e\u003cstrong data-start=\"2282\" data-end=\"2300\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel cylinder\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2329\" data-end=\"2468\" class=\"\"\u003e \u003cp data-start=\"2331\" data-end=\"2468\" class=\"\"\u003e\u003cstrong data-start=\"2331\" data-end=\"2343\"\u003eStorage:\u003c\/strong\u003e Store in a cool, dry, and ventilated area. Keep away from heat sources and direct sunlight. Do not store above 52°C (125°F).\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Friglab","offers":[{"title":"Default Title","offer_id":54108878995785,"sku":"PZ-404","price":99.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/9691\/0409\/files\/1_1_ed732cd3-7e9f-4784-96e4-b98369736648.jpg?v=1774879521"},{"product_id":"r134a-freon-refrigerant","title":"30LB R134A R-134A Freon Refrigerant Gas","description":"\u003cp data-start=\"185\" data-end=\"570\" class=\"\"\u003eR-134A, chemically known as 1,1,1,2-Tetrafluoroethane, has become a widely used refrigerant in automotive air conditioning systems and commercial refrigeration since the global phaseout of ozone-depleting substances. Its excellent thermodynamic properties and environmental safety compared to legacy refrigerants like R12 make it a go-to solution for a variety of cooling applications.\u003c\/p\u003e \u003chr data-start=\"572\" data-end=\"575\" class=\"\"\u003e \u003ch5 data-start=\"577\" data-end=\"611\"\u003e\u003cstrong data-start=\"581\" data-end=\"611\"\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"613\" data-end=\"820\" class=\"\"\u003e✅ \u003cstrong data-start=\"615\" data-end=\"646\"\u003eOzone-friendly performance:\u003c\/strong\u003e R-134A contains no chlorine and has zero ozone depletion potential (ODP), making it an environmentally safer option that complies with international environmental standards.\u003c\/p\u003e \u003cp data-start=\"822\" data-end=\"1026\" class=\"\"\u003e✅ \u003cstrong data-start=\"824\" data-end=\"853\"\u003eWide usage compatibility:\u003c\/strong\u003e Commonly used in automotive A\/C systems, commercial refrigeration units, and other medium-temperature applications. Ideal for both original equipment and retrofit projects.\u003c\/p\u003e \u003cp data-start=\"1028\" data-end=\"1181\" class=\"\"\u003e✅ \u003cstrong data-start=\"1030\" data-end=\"1054\"\u003eThermally efficient:\u003c\/strong\u003e Offers stable performance with good cooling efficiency and moderate operating pressures, reducing stress on system components.\u003c\/p\u003e \u003cp data-start=\"1183\" data-end=\"1352\" class=\"\"\u003e✅ \u003cstrong data-start=\"1185\" data-end=\"1212\"\u003eNon-flammable and safe:\u003c\/strong\u003e Classified as A1 by ASHRAE, R-134A is non-flammable and low toxicity, making it a safe and reliable choice for technicians and users alike.\u003c\/p\u003e \u003chr data-start=\"1354\" data-end=\"1357\" class=\"\"\u003e \u003ch5 data-start=\"1359\" data-end=\"1393\"\u003e\u003cstrong data-start=\"1363\" data-end=\"1393\"\u003eR-134A Physical Properties\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"1395\" data-end=\"1607\"\u003e \u003cli data-start=\"1395\" data-end=\"1443\" class=\"\"\u003e \u003cp data-start=\"1397\" data-end=\"1443\" class=\"\"\u003e\u003cstrong data-start=\"1397\" data-end=\"1415\"\u003eChemical Name:\u003c\/strong\u003e 1,1,1,2-Tetrafluoroethane\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1444\" data-end=\"1477\" class=\"\"\u003e \u003cp data-start=\"1446\" data-end=\"1477\" class=\"\"\u003e\u003cstrong data-start=\"1446\" data-end=\"1468\"\u003eMolecular Formula:\u003c\/strong\u003e C₂H₂F₄\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1478\" data-end=\"1518\" class=\"\"\u003e \u003cp data-start=\"1480\" data-end=\"1518\" class=\"\"\u003e\u003cstrong data-start=\"1480\" data-end=\"1498\"\u003eBoiling Point:\u003c\/strong\u003e -26.3°C (-15.3°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1519\" data-end=\"1564\" class=\"\"\u003e \u003cp data-start=\"1521\" data-end=\"1564\" class=\"\"\u003e\u003cstrong data-start=\"1521\" data-end=\"1556\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 1,430\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1565\" data-end=\"1607\" class=\"\"\u003e \u003cp data-start=\"1567\" data-end=\"1607\" class=\"\"\u003e\u003cstrong data-start=\"1567\" data-end=\"1603\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1609\" data-end=\"1612\" class=\"\"\u003e \u003ch5 data-start=\"1614\" data-end=\"1639\"\u003e\u003cstrong data-start=\"1618\" data-end=\"1639\"\u003eMain Applications\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1641\" data-end=\"1761\" class=\"\"\u003e\u003cstrong data-start=\"1641\" data-end=\"1680\"\u003eAutomotive Air Conditioning Systems\u003c\/strong\u003e\u003cbr data-start=\"1680\" data-end=\"1683\"\u003eWidely used in passenger vehicles, trucks, and buses as a replacement for R12.\u003c\/p\u003e \u003cp data-start=\"1763\" data-end=\"1924\" class=\"\"\u003e\u003cstrong data-start=\"1763\" data-end=\"1804\"\u003eCommercial and Domestic Refrigeration\u003c\/strong\u003e\u003cbr data-start=\"1804\" data-end=\"1807\"\u003eIdeal for medium-temperature refrigeration such as beverage coolers, display cases, vending machines, and ice makers.\u003c\/p\u003e \u003cp data-start=\"1926\" data-end=\"2047\" class=\"\"\u003e\u003cstrong data-start=\"1926\" data-end=\"1958\"\u003eHeat Pumps and Dehumidifiers\u003c\/strong\u003e\u003cbr data-start=\"1958\" data-end=\"1961\"\u003eWorks effectively in appliances that require moderate-temperature cooling and heating.\u003c\/p\u003e \u003chr data-start=\"2049\" data-end=\"2052\" class=\"\"\u003e \u003ch5 data-start=\"2054\" data-end=\"2097\"\u003e\u003cstrong data-start=\"2058\" data-end=\"2095\"\u003eNote on Environmental Regulations\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"2098\" data-end=\"2416\" class=\"\"\u003eWhile R-134A is ozone-friendly, its GWP is relatively high. Regulations in some regions are gradually restricting its use in certain new equipment. However, it remains a reliable and legal option for servicing and maintaining existing systems. Always follow regional and national guidelines when handling refrigerants.\u003c\/p\u003e \u003chr data-start=\"2418\" data-end=\"2421\" class=\"\"\u003e \u003ch5 data-start=\"2423\" data-end=\"2438\"\u003e\u003cstrong data-start=\"2427\" data-end=\"2438\"\u003ePackage\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"2440\" data-end=\"2683\"\u003e \u003cli data-start=\"2440\" data-end=\"2501\" class=\"\"\u003e \u003cp data-start=\"2442\" data-end=\"2501\" class=\"\"\u003e\u003cstrong data-start=\"2442\" data-end=\"2456\"\u003ePackaging:\u003c\/strong\u003e Net Weight 13.6kg\/bottle (Net Weight 30lb)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2502\" data-end=\"2550\" class=\"\"\u003e \u003cp data-start=\"2504\" data-end=\"2550\" class=\"\"\u003e\u003cstrong data-start=\"2504\" data-end=\"2522\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel cylinder\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2551\" data-end=\"2683\" class=\"\"\u003e \u003cp data-start=\"2553\" data-end=\"2683\" class=\"\"\u003e\u003cstrong data-start=\"2553\" data-end=\"2565\"\u003eStorage:\u003c\/strong\u003e Store in a cool, dry, and well-ventilated area. Avoid exposure to direct sunlight or temperatures above 52°C (125°F).\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Friglab","offers":[{"title":"Default Title","offer_id":54108879094089,"sku":"PZ-134","price":99.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/9691\/0409\/files\/1_5_8191dbf4-6c59-4c71-a744-ee8d31353c42.jpg?v=1774879523"},{"product_id":"r410a-freon-refrigerant","title":"25LB R410A R-410A Freon Refrigerant Gas","description":"\u003cp data-start=\"161\" data-end=\"525\" class=\"\"\u003eR-410A, a near-azeotropic blend of HFC-32 and HFC-125, is the standard refrigerant in new residential and light commercial air conditioning systems. Known for its excellent energy efficiency and zero ozone depletion potential, R-410A is engineered to deliver superior performance in high-pressure systems, making it the go-to replacement for outdated R-22 systems.\u003c\/p\u003e \u003chr data-start=\"527\" data-end=\"530\" class=\"\"\u003e \u003ch5 data-start=\"532\" data-end=\"566\"\u003e\u003cstrong data-start=\"536\" data-end=\"566\"\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"568\" data-end=\"765\" class=\"\"\u003e✅ \u003cstrong data-start=\"570\" data-end=\"599\"\u003eEco-friendly composition:\u003c\/strong\u003e R-410A contains no chlorine, giving it an ODP of 0. It complies with global environmental standards and is safer for the ozone layer compared to legacy refrigerants.\u003c\/p\u003e \u003cp data-start=\"767\" data-end=\"925\" class=\"\"\u003e✅ \u003cstrong data-start=\"769\" data-end=\"797\"\u003eHigh cooling efficiency:\u003c\/strong\u003e Offers greater energy efficiency and better heat transfer capabilities than R-22, making it ideal for high-performance systems.\u003c\/p\u003e \u003cp data-start=\"927\" data-end=\"1081\" class=\"\"\u003e✅ \u003cstrong data-start=\"929\" data-end=\"967\"\u003eReliable in high-pressure systems:\u003c\/strong\u003e Designed to operate at higher pressures, R-410A supports more compact components and improved system performance.\u003c\/p\u003e \u003cp data-start=\"1083\" data-end=\"1232\" class=\"\"\u003e✅ \u003cstrong data-start=\"1085\" data-end=\"1106\"\u003eWidely supported:\u003c\/strong\u003e Compatible with modern HVAC equipment and synthetic lubricants (POE oil), ensuring easy servicing and component availability.\u003c\/p\u003e \u003chr data-start=\"1234\" data-end=\"1237\" class=\"\"\u003e \u003ch5 data-start=\"1239\" data-end=\"1273\"\u003e\u003cstrong data-start=\"1243\" data-end=\"1273\"\u003eR-410A Physical Properties\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"1275\" data-end=\"1455\"\u003e \u003cli data-start=\"1275\" data-end=\"1325\" class=\"\"\u003e \u003cp data-start=\"1277\" data-end=\"1325\" class=\"\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1302\"\u003eChemical Composition:\u003c\/strong\u003e 50% R-32 \/ 50% R-125\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1326\" data-end=\"1366\" class=\"\"\u003e \u003cp data-start=\"1328\" data-end=\"1366\" class=\"\"\u003e\u003cstrong data-start=\"1328\" data-end=\"1346\"\u003eBoiling Point:\u003c\/strong\u003e -48.5°C (-55.3°F)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1367\" data-end=\"1412\" class=\"\"\u003e \u003cp data-start=\"1369\" data-end=\"1412\" class=\"\"\u003e\u003cstrong data-start=\"1369\" data-end=\"1404\"\u003eGWP (Global Warming Potential):\u003c\/strong\u003e 2,088\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1413\" data-end=\"1455\" class=\"\"\u003e \u003cp data-start=\"1415\" data-end=\"1455\" class=\"\"\u003e\u003cstrong data-start=\"1415\" data-end=\"1451\"\u003eODP (Ozone Depletion Potential):\u003c\/strong\u003e 0\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr data-start=\"1457\" data-end=\"1460\" class=\"\"\u003e \u003ch5 data-start=\"1462\" data-end=\"1487\"\u003e\u003cstrong data-start=\"1466\" data-end=\"1487\"\u003eMain Applications\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1489\" data-end=\"1659\" class=\"\"\u003e\u003cstrong data-start=\"1489\" data-end=\"1532\"\u003eResidential and Commercial HVAC Systems\u003c\/strong\u003e\u003cbr data-start=\"1532\" data-end=\"1535\"\u003eCommonly used in split-type air conditioners, central A\/C units, and packaged rooftop systems for both homes and businesses.\u003c\/p\u003e \u003cp data-start=\"1661\" data-end=\"1822\" class=\"\"\u003e\u003cstrong data-start=\"1661\" data-end=\"1693\"\u003eHeat Pumps and Dehumidifiers\u003c\/strong\u003e\u003cbr data-start=\"1693\" data-end=\"1696\"\u003ePreferred refrigerant for newer high-efficiency heat pump models and air treatment systems requiring reliable climate control.\u003c\/p\u003e \u003cp data-start=\"1824\" data-end=\"1935\" class=\"\"\u003e\u003cstrong data-start=\"1824\" data-end=\"1855\"\u003eNew Equipment Installations\u003c\/strong\u003e\u003cbr data-start=\"1855\" data-end=\"1858\"\u003eWidely adopted as the industry standard for systems built post-R-22 phaseout.\u003c\/p\u003e \u003chr data-start=\"1937\" data-end=\"1940\" class=\"\"\u003e \u003ch5 data-start=\"1942\" data-end=\"1985\"\u003e\u003cstrong data-start=\"1946\" data-end=\"1983\"\u003eNote on Environmental Regulations\u003c\/strong\u003e\u003c\/h5\u003e \u003cp data-start=\"1986\" data-end=\"2293\" class=\"\"\u003eWhile R-410A is ozone-friendly, its GWP is still significant. It is gradually being phased down in favor of next-generation refrigerants with lower environmental impact. For existing equipment, R-410A remains fully legal and essential for maintenance. Always adhere to local refrigerant handling guidelines.\u003c\/p\u003e \u003chr data-start=\"2295\" data-end=\"2298\" class=\"\"\u003e \u003ch5 data-start=\"2300\" data-end=\"2315\"\u003e\u003cstrong data-start=\"2304\" data-end=\"2315\"\u003ePackage\u003c\/strong\u003e\u003c\/h5\u003e \u003cul data-start=\"2317\" data-end=\"2566\"\u003e \u003cli data-start=\"2317\" data-end=\"2378\" class=\"\"\u003e \u003cp data-start=\"2319\" data-end=\"2378\" class=\"\"\u003e\u003cstrong data-start=\"2319\" data-end=\"2333\"\u003ePackaging:\u003c\/strong\u003e Net Weight 11.3kg\/bottle (Net Weight 25lb)\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2379\" data-end=\"2427\" class=\"\"\u003e \u003cp data-start=\"2381\" data-end=\"2427\" class=\"\"\u003e\u003cstrong data-start=\"2381\" data-end=\"2399\"\u003eCylinder Type:\u003c\/strong\u003e Disposable steel cylinder\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2428\" data-end=\"2566\" class=\"\"\u003e \u003cp data-start=\"2430\" data-end=\"2566\" class=\"\"\u003e\u003cstrong data-start=\"2430\" data-end=\"2442\"\u003eStorage:\u003c\/strong\u003e Store in a cool, dry, and shaded location. Avoid temperatures above 52°C (125°F). Handle with appropriate safety equipment.\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e","brand":"Friglab","offers":[{"title":"Default Title","offer_id":54108879192393,"sku":"PZ-D41","price":99.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/9691\/0409\/files\/1_1_6f61a5f7-64bd-4179-bdaf-9fe8dab1c4bd.jpg?v=1774879524"}],"url":"https:\/\/friglab.shop\/collections\/best-selling.oembed","provider":"padyala","version":"1.0","type":"link"}